Products

Portable dissolved oxygen meter

Current Location : Home > Products > Dissolved oxygen > Portable dissolved oxygen meter
News

DOS-1707 Laboratory Dissolved Oxygen Meter

DOS-1707 ppm level portable Desktop Dissolved Oxygen Meter is one of the electrochemical analyzers used in laboratory and a high-intelligence continuous monitor produced by our company. It can be equipped with the DOS-808F Polarographic Electrode, achieving a wide range ppm level automatic measurement. It is a special instrument used for testing the oxygen content of the solutions in the boiler feed water, condensate water, environmental protection sewage and other industries. Technical indexesMeasuring range DO 0.00--50.0mg/L 0.0--500% Temp 0…60℃ (ATC/MTC) Atmosphere 300--1100hPaResolution DO 0.01mg/L,0.1mg/L(ATC) 0.1%/1%(ATC) Temp 0.1℃ Atmosphere 1hPaElectronic unit measurement error DO ±0.5 % FS Temp ±0.2 ℃ Atmosphere ±5hPaCalibration At most 2 point, (water vapor saturated air/zero oxygen solution)Power supply DC6V/20mA; 4 x AA/LR6 1.5 V or NiMH 1.2 V and chargableSize/Weight 230×100×35(mm)/0.4kgDisplay LCD Sensor input connector BNCData storage Calibration data;99 groups measurement dataWorking condition Temp 5...40℃ Relative humidity 5%...80% (without condensate) Installation grade Ⅱ Pollution grade 2 Altitude <=2000m
DOS-1707 Laboratory Dissolved Oxygen Meter
  • Details
  • 询价

DOS-1707 Laboratory Dissolved Oxygen Meter

 

DOS-1707 ppm level portable Desktop Dissolved Oxygen Meter is one of the electrochemical analyzers used in laboratory and a high-intelligence continuous monitor produced by our company. It can be equipped with the DOS-808F Polarographic Electrode, achieving a wide range ppm level automatic measurement. It is a special instrument used for testing the oxygen content of the solutions in the boiler feed water, condensate water, environmental protection sewage and other industries.

 

Technical indexes

Measuring range

DO

0.00--50.0mg/L

0.0--500%

Temp

0…60℃ ATC/MTC

Atmosphere

300--1100hPa

Resolution

DO

0.01mg/L,0.1mg/L(ATC

0.1%/1%(ATC

Temp

0.1℃

Atmosphere

1hPa

Electronic unit measurement error

DO

±0.5 % FS

Temp

±0.2 ℃

Atmosphere

±5hPa

Calibration

At most 2 point, (water vapor saturated air/zero oxygen solution)

Power supply

DC6V/20mA; 4 x AA/LR6 1.5 V or  NiMH 1.2 V and chargable

Size/Weight

230×100×35(mm)/0.4kg

Display

LCD

Sensor input connector

BNC

Data storage

Calibration data99 groups measurement data

Working condition

Temp

5...40℃

Relative humidity

5%...80% (without condensate)

Installation grade

Pollution grade

2

Altitude

<=2000m

Product inquiry
*
*